CT PT Test Equipment

(34)
China High Voltage Source CVT Testing , 60HZ Capacitive Voltage Transformer Testing factory

High Voltage Source CVT Testing , 60HZ Capacitive Voltage Transformer Testing
Contact Now

200KV High Voltage Source & Control Cabinet HEW-20 CVT Test System Testing system configuration No Product Description 1 Control Cabinet 2 Testing Transformer 3 Testing Cables General Specification Product ... Read More
2021-09-27 09:58:12
China 0.2 Class CT PT Test Equipment Electromagnetic Type VT factory

0.2 Class CT PT Test Equipment Electromagnetic Type VT
Contact Now

CT/PT Ratio & Polarity Tester MCVT-RP01 Technical Index Ratio test range 5A/5A-25000A/5A, 5A/1A-5000A/1A Test object type various CT and all electromagnetic type VT Test accuracy 0.2% Dimension 280*230*100mm ... Read More
2021-09-27 09:58:12
China Digital Portable Testing Equipment , IEC61850 Transformer Test Set factory

Digital Portable Testing Equipment , IEC61850 Transformer Test Set
Contact Now

Digital CT VT Tester/Calibrator HEWD-2A Technical Parameter Rated Primary voltage measureup to 500KVRated primary current measure5-5000A, customization availableStandard signal inputVoltage input0-120%Un, Un... Read More
2021-09-27 09:58:12
China 50Hz Manual CT PT Test Equipment With Burden Box Collection factory

50Hz Manual CT PT Test Equipment With Burden Box Collection
Contact Now

Accuracy Class 3 CT PT burden box collection FY47 CT Burden Technical Parameters T Rated Current: 1A Power Factor and Rated Burden: COSΦ=0.8:0.625,1.25,2.5,3.75,5,6.25,7.5,10,12.5,15,20,25,30,40,50,60VA COSΦ=1... Read More
2021-09-27 09:58:12
China Automatic Voltage Transformer Burden With Air Insulation factory

Automatic Voltage Transformer Burden With Air Insulation
Contact Now

Manual or Automatic CT VT Burden box FYC series FYC47-49 CT Burden Technical Parameter Rated Current: 5A, 1A Power Factor and Rated Burden: COSΦ=0.8: 5VA, 10VA, 15VA, 20VA, 30VA COSΦ=1.0: 1VA, 2VA, 5VA Accuracy ... Read More
2021-09-27 09:58:12
China 0.01 Class Current Potential Transformer With Generator Double Stages factory

0.01 Class Current Potential Transformer With Generator Double Stages
Contact Now

0.01 Class Double Stage Standard PT with voltage Generator Technical Parameter Rated voltage ratio 6,10,35Kv/100V, 6,10,35/√3Kv /100/√3V Rated secondary capacity 0.2VA,0.07VA CosФ=1.0 Accuracy class 0.05, 0.02, ... Read More
2021-09-27 09:58:12
China 3% Touch Screen CT PT Test Equipment As Secondary Load factory

3% Touch Screen CT PT Test Equipment As Secondary Load
Contact Now

Intelligent Type Potential Transformer Burden Box VT Burden FY96 Technical Parameter Rated Current 100V, 100/√3, 110V, 110/√3more (option) Operating Range 1-200% Rated load (VA) COSφ= 0.8: 1.25-158.75 Rated ... Read More
2021-09-27 09:58:12
China 60HZ CT PT Test Equipment With Current Transformer Burden Box factory

60HZ CT PT Test Equipment With Current Transformer Burden Box
Contact Now

Intelligent Type Current Transformer Burden Box CT Burden FY61A Technical Parameter Rated Current 5A, 1A Operating Range 1-120% Rated Impedance (Ω) COSφ= 0.8 0.1;0.15;0.2;0.3;0.4;;0.6;1.0;1.2; 1.6; 2.4; 3.2 COS... Read More
2021-09-27 09:58:12
China LED CT PT Testing , 5A Current Transformer Burden Test factory

LED CT PT Testing , 5A Current Transformer Burden Test
Contact Now

Intelligent Type Current Transformer Burden Box CT Burden FL2 series Working as secondary load during current transformer testing Full automatic Can provide communication protocol Technical Parameter Rated ... Read More
2021-09-27 09:58:12
China Digital CT PT Test Equipment Comparator With LCD Display factory

Digital CT PT Test Equipment Comparator With LCD Display
Contact Now

Digital Transformer Tester HEW series CT PT Comparator Technical Parameter Accuracy class 2 Current range 5A, 1A Voltage range 100V,100/√3V Percentage Error Less than 1.5%*FS Basic Error When testing CT PT ... Read More
2021-09-27 09:58:12