Product Details:
Payment & Shipping Terms:
|
Standard CT Class: | 0.01S, 0.05, 0.02, 0.01...optional | Standard PT: | 0.05 Class |
---|---|---|---|
Current Range: | 5-5000A, Or More For Option | Voltage Range: | 6KV-38.5KV |
CT, PT Burden Accuracy: | 3% | Transformer Tester: | 2% |
Highlight: | 38.5KV CT PT Test Equipment,5000A CT PT Test Equipment,0.01S CT PT Test Equipment |
CT PT TEST Equipment System HES-30
Configuration
Standard CT, ±0.01S% |
Standard PT (6kV-38.5kV), ±0.05% |
CT Burden (5A, 1A), ±3% |
PT Burden (100V, 100/√3V, 100/3V), ±3% |
PT Burden (110V, 110/√3V, 110/3V), ±3% |
Transformer Tester (Calibrator), ±2% |
Current generator |
Voltage Generator |
Secondary Test Cables |
PC Test Software |
CT PT Test Control Bench |
Technical Parameter
HES-30 CT/PT Test Control Bench
Input Voltage: | AC 220V±10%, 50Hz, Single-Phase |
Input Current: | AC 0-120A |
Rated Capacity: | 30kVA |
Output Voltage: | AC 0-250V |
Output Current: | AC 0-120A |
Output Voltage Adjustment: | Provided the Coarse adjustment & Fine adjustment |
Protection function: | Provided over current & overvoltage protection |
Output conversion functions: | Connect to Current source / Voltage source conversion functions |
The Bench Structure: | Horizontal structure |
Power Indicator: | LED, Output current, Output voltage |
Color of the Bench | 7035 Gray |
HES-1Bx Transformer Tester
Measure item: | Ratio errors & Phase errors of the CT and PT |
Rated current: | 5A, 1A |
Rated voltage: | 100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V |
Multiplier: | 1/√3, 1/3, 1, 1.5, 2 |
Accuracy class: | ±2% |
Operation range: | (1%-120%).In, (20%-120%).Un |
Frequency: | 50Hz or 60Hz |
Ratio error range: | ±0.0001% ~ ±19.99% (3 ranges: 0.1999%, 1.999%, 19.99%). |
Minimum resolution:0.0001%. | |
Phase error range: | 0.01' ~ ±900' (3 ranges: 9.00', 90.0', 900') |
Minimum resolution: 0.01' | |
Impedance range: | 0.001Ω~ 19.99Ω. |
Minimum resolution: 0.001Ω. | |
Admittance range: | 0.001 ms ~ 19.99 ms. |
Minimum resolution:0.001 ms. | |
Alarm Function: | Provided the sound & light alarm function when the polarity abnormal or ratio inconsistent. |
Input Load: |
- On Standard CT secondary side: ≈0.11Ω, COSφ≈1.0 - On Test Object CT secondary side: ≈0.003Ω, COSφ≈1.0 - On Standard PT secondary side: ≈0.05VA (100V) |
Communication Interface: | Provided the RS232 serial PC communication interface |
Display model: | LCD |
Power supply: | AC 220V±10%, 60Hz |
Power consumption: | < 20VA |
Product Type: |
Portable type |
CT Burden FY47-49
Rated Current: | 5A, 1A |
Power Factor and Rated Burden: |
In=5A: COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA (more option available) In=1A: COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA (more option available) |
Accuracy Class: | ±3% |
Operation Range: | (1%-120%). In |
Frequency: | 50Hz or 60Hz |
Withstand Voltage: | 2kV/1min |
Insulation: | Air |
Operating Model: | Short-time (Used in CT Accuracy Testing System) |
Product Type: | Portable type. |
High-current Test Cables of the CT
Cables includes: 3000A(600mm2) x 3m x 2pcs, 1000A(200mm2) x 5m x 1pc
500A(100mm2) x 3m x 2pcs, 250A(50mm2) x 3m x 2pcs
HLB-50G1 Standard CT
Rated Primary Current(A): |
5, 7.5, 10, 12.5, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 125, 150, 160, 200, 250, 300, 315, 350, 400, 450, 500, 600, 630, 700, 750, 800, 900, 1000, 1200, 1250, 1400, 1500, 1600, 1800, 2000, 2500, 3000, 3150, 3500, 4000, 4500, 5000A (more option available) |
Rated Secondary Current: | 5A, 1A |
Rated Current Ratio: | 5A~5000A/5A, 5A~5000A/1A (more option available) |
Accuracy Class: | 0.01S% (0.05%, 0.02%, 0.01% or better are available) |
Rated Secondary Burden: | 0.2Ω (Burden is 5VA at I2 = 5A, Burden is 0.2VA at I2 = 1A) |
Power Factor: | COSΦ=1.0 |
Operating Range: | (1%-120%). In |
Connection Mode: |
Fixed connection terminals at Pri.current range is 5A-450A Pass-through connection with 2 turns at Pri.current range is 500A-900A Pass-through connection with 1 turn at Pri.current range is 1000A-5000A |
Frequency: | 50Hz or 60Hz |
Voltage Level: | AC 600V |
Withstand Voltage: | 2000V 1min |
Insulating Medium: | Air |
SLQ-30KVA Current Generator
Input Voltage: | AC 0-250V |
Output Current: | AC 0-5000A |
Rated Capacity: | 30kVA |
Rated Input Current: | AC 120A |
Frequency: | 50Hz or 60Hz |
Current Output Model: |
Fixed terminal at current is 50A, 200A, 500A Through-hole connection at current is 500A-5000A |
Products Shape: | Stainless Steel Box |
Working condition: | 0 - 40ºC, RH ≤ 90% |
FY95-1 PT Burden
Rated Voltage: | 100V, 100/√3V, 100/3V |
Power Factor: | COSФ=0.8, COSФ=1.0 |
Rated Burden (VA): |
1.25VA, 2.5VA, 5VA, 10VA, 20VA, 40VA, 50VA, 80VA, 100VA (more option available) |
Total Output Burden: | 308.75VA (more option available) |
Accuracy Class: | ±3% |
Operation Range: | (20%-120%). Un |
Frequency: | 50Hz or 60Hz |
Withstand Voltage: | 2kV/1min |
Insulation: | Air |
Operating Model: | Short-time (Used in PT Accuracy Testing System) |
HJB-35G3 Standard PT
Rated Primary Voltage: | 6kV, 10kV, 15kV, 22kV, 35kV, 38.5kV |
Rated Secondary Voltage: | 100V,110V,100/√3V,110/√3V,100/3V,110/3V |
Rated Voltage Ratio (kV): |
6/0.1, 6/√3/0.1/√3, 6/√3/0.1/3, 6/0.11, 6/√3/0.11/√3, 6/√3/0.11/3 10/0.1, 10/√3/0.1/√3, 10/√3/0.1/3, 10/0.11, 10/√3/0.11/√3, 10/√3/0.11/3 15/0.1, 15/√3/0.1/√3, 15/√3/0.1/3, 15/0.11, 15/√3/0.11/√3, 15/√3/0.11/3 22/0.1, 22/√3/0.1/√3, 22/√3/0.1/3, 22/0.11, 22/√3/0.11/√3, 22/√3/0.11/3 35/0.1, 35/√3/0.1/√3, 35/√3/0.1/3, 35/0.11, 35/√3/0.11/√3, 35/√3/0.11/3 38.5/0.1, 38.5/√3/0.1/√3, 38.5/√3/0.1/3, 38.5/0.11, 38.5/√3/0.11/√3, 38.5/√3/0.11/3 |
Accuracy Class: | 0.05% (100V,110V,100/√3V,110/√3V), 0.1% (100/3V,110/3V) |
Rated Secondary Burden: | 0.2VA(110V, 100V), 0.07VA(110/√3V, 100/√3V), 0.02VA(110/3V, 100/3V) |
Power Factor: | COSΦ=1.0 |
Operating Range: | (20%-120%). Un |
Frequency: | 50Hz or 60Hz |
Insulation: | Epoxy resin casting |